Function & Field of application
2/2-way MAXI solenoid valve
Technical Data
[{"K_Techdat1":"Anschluss","K_Techdat2":"Withworth-Rohrgewinde G3\/8\" bis G1\"","K_Techdat3":"","K_Techdat4":"","K_Techdat5":"","K_Techdat6":""},{"K_Techdat1":"Bauart","K_Techdat2":"Sitzventil mit Tellerdichtung","K_Techdat3":"","K_Techdat4":"","K_Techdat5":"","K_Techdat6":""},{"K_Techdat1":"Druckbereich","K_Techdat2":"0 bis 16 bar auch für Vakuum geeignet","K_Techdat3":"","K_Techdat4":"","K_Techdat5":"","K_Techdat6":""},{"K_Techdat1":"Temperaturbereich","K_Techdat2":"NBR: -10°C bis +80°C\r\nFKM und EPDM: -10°C bis +130°C","K_Techdat3":"","K_Techdat4":"","K_Techdat5":"","K_Techdat6":""},{"K_Techdat1":"Einbaulage","K_Techdat2":"beliebig","K_Techdat3":"","K_Techdat4":"","K_Techdat5":"","K_Techdat6":""},{"K_Techdat1":"Viskosität","K_Techdat2":"max. 10 Grad E","K_Techdat3":"","K_Techdat4":"","K_Techdat5":"","K_Techdat6":""},{"K_Techdat1":"Elektrische Daten","K_Techdat2":"","K_Techdat3":"","K_Techdat4":"","K_Techdat5":"","K_Techdat6":""},{"K_Techdat1":"Spulen-Temp.-Klasse","K_Techdat2":"F (+155°C)","K_Techdat3":"","K_Techdat4":"","K_Techdat5":"","K_Techdat6":""},{"K_Techdat1":"Einschaltdauer","K_Techdat2":"100% ED","K_Techdat3":"","K_Techdat4":"","K_Techdat5":"","K_Techdat6":""},{"K_Techdat1":"Schutzart","K_Techdat2":"IP 65 (mit Stecker DIN 43650)","K_Techdat3":"","K_Techdat4":"","K_Techdat5":"","K_Techdat6":""},{"K_Techdat1":"Standardspannungen","K_Techdat2":"24V, 110V, 230V","K_Techdat3":"12V, 24V","K_Techdat4":"","K_Techdat5":"","K_Techdat6":""},{"K_Techdat1":"Spule C3","K_Techdat2":"13 VA (Halten) \/ 20 VA (Anzug)","K_Techdat3":"8,0 W","K_Techdat4":"","K_Techdat5":"","K_Techdat6":""},{"K_Techdat1":"Spule C4","K_Techdat2":"22 VA (Halten) \/ 40 VA (Anzug)","K_Techdat3":"27 W","K_Techdat4":"","K_Techdat5":"","K_Techdat6":""},{"K_Techdat1":"Spannungstoleranz","K_Techdat2":"-15% bis +10%","K_Techdat3":"-5% bis +10%","K_Techdat4":"","K_Techdat5":"","K_Techdat6":""},{"K_Techdat1":"Achtung! Die Installation dieser Artikel erfordert immer eine Elektro-Fachkraft, sofern diese nicht mit einer sicheren Kleinspannung (SELV, PELV, ...) betrieben werden!","K_Techdat2":"","K_Techdat3":"","K_Techdat4":"","K_Techdat5":"","K_Techdat6":""}]
23110702-24V/50HZ
Valve design:
2/2 way
flow gaseous media 6 bar Nl/min:
5732
nominal width:
19
Special Characteristics:
2/2-Wege- Maxi-Magnetventil
zwangsgesteuert - NG
in Ruhestellung geschlossen
Ko…
Price per piece
Available in 1 day, delivery time 1-3 days
23110700-230/50
Valve design:
2/2 way
flow gaseous media 6 bar Nl/min:
2229
nominal width:
12.7
Special Characteristics:
2/2-Wege- Maxi-Magnetventil
zwangsgesteuert - NG
in Ruhestellung geschlossen
Ko…
Product Specific Download:
Katalog
Katalog
Price per piece
Available in 12 days, delivery time 1-3 days